A uniform egg shell temperature throughout an incubator is crucial for obtaining good results. As egg shell temperature depends on the balance between heat production and heat loss, a uniform heat loss is therefore an important parameter in the quality of the incubation process.

Heat loss is dependent on the temperature difference between egg and air, on evaporative cooling and on air velocity. This makes it crucial that both evaporative cooling and air velocity over the eggs is as uniform as possible.

We can identify different incubators by different characteristics, and one of them is how uniform the air velocity over the eggs will be. An incubator that only moves the air more or less randomly throughout the machine will most probably not have a uniform air velocity, as air takes the way of the least resistance, which means that it will not easily pass through trolleys and trays but will try to move between the individual trolleys and the open spaces between trolleys and walls, floors and ceilings.

In that respect one would expect that an tunnel type incubator where the air is forced through the tunnel and with it through the trolleys and trays, would have a more uniform egg shell temperature, and that is often the case. As the air picks up the heat from the eggs it needs to be cooled between the trolleys, but with a good design that can be done.

However, we often see that in these tunnel type machines, both multi stage and single stage, the bottom trays close to the position where the air is entering the tunnel are somewhat cooler than the eggs higher up in the trolley. It is often thought that this is the result of a difference in air velocity, but this is not very likely.

Air velocity is the result of a difference in air pressure, and according to the laws of Pascal, air pressure is distributed equally in a room. That means that if the openings (either holes in a radiator in front of the trolleys or the opening between the trays in that trolley) are equally distributed, the amount of air that will go through and with it the air velocity in top and bottom will be equal. And when we measure the air speed in top and bottom, we see that there is hardly any difference at all, so the laws of Mr. Pascal (1623-1662) still seem to be valid.

So what causes the temperature difference? It is actually not the air velocity but the evaporative cooling. When we spray water in the air, this water has a mass. And the laws of Mr. Newton (1642-1727) dictate that an object with mass will try to continue in the direction it is moving. This means that when we spray water in the air and we force this air to make a turn to be redistributed in front of the trolleys, the water droplets in the air will tend to go straight as much as possible. So, although the air will be redistributed in front of the first trolley because of the law of Mr. Pascal, the law of Mr. Newton will result in an accumulation of water droplets in the bottom of the trolley, resulting in more local evaporation and more local cooling and a difference in egg shell temperature between top and bottom.

This means that the more we spray, the more we will see a difference between top and bottom, especially in the first trolley where the air enters the tunnel. Further inwards the temperature difference will disappear and the eggs will be more uniform in temperature. This means it is beneficial to shut the sprayer off. As the relative humidity which is the result of the spraying is only responsible for weight loss of the eggs and in most single stage machines the weight loss is at or below optimum, there is no problem to shut off the sprayer if there is enough cooling. If there is not enough cooling capacity like in the older multi stage tunnel machines, we cannot switch off the sprayer as we need the evaporative cooling.